CERIS NOVA - Civil Engineering Research & Innovation for Sustainability
Scopus Publications
Scholar Citations
Scholar h-index
Scholar i10-index
Hugo Entradas Silva and Fernando M. A. Henriques
MDPI AG
Museums housed in historical buildings combine the intrinsic value of the collections with the historical and architectural values of the building itself. Although usually made with thick elements with high thermal inertia, very effective in damping and delaying the heat flow, these buildings are usually characterized by elements with low thermal resistance, poor-quality windows and low area/volume ratio in the noblest buildings, which renders them ineffective at maintaining a stable indoor climate adequate for conservation, comfort and energy efficiency issues. In this paper, a simulation study was carried out to analyze the impact of the building location (weather), thermal envelope and climate control strategies by analyzing a generic room of the National Museum of Ancient Art of Lisbon. A simulation study was carried out for 15 European cities to verify the impossibility of standardizing the rehabilitation solutions in cultural heritage since energy needs depend on the location. It was concluded that the focus on climate control strategies has great potential for energy reduction and that in temperate climates of southern Europe, the improvement of thermal transmittance has a reduced effect on the building’s response.
Luis G. Baltazar, João Alcobia, and Hugo Entradas Silva
MDPI AG
Visitors have a significant impact on the indoor climate of buildings housing works of art, and the relationship between the number of visitors, the indoor air quality and the protection of exposed works of art is an important factor in the overall study of the indoor climate of heritage buildings without mechanical ventilation and/or air-conditioning systems. In view of these concerns and the lack of studies on natural ventilation in heritage buildings, this study aims to analyse the performance of natural ventilation in the São Cristóvão Church in Lisbon, Portugal. For the preparation of this study, an analysis of the natural ventilation of this church was carried out by creating a model in the CONTAM software, and the indoor air quality was analysed based on different international standards and guidelines for carbon dioxide levels and air flow rates (ACH). Estimating the current ventilation strategy, an average ACH of 0.75 h−1 was estimated during the time the church is open, and an ACH of 0.15 h−1 was estimated during the time the doors were closed. In a yearly analysis, an average ACH of 0.30 h−1 was obtained. These air exchange values guarantee EN 16798-1 category I air quality for 72% of the year and category II air quality for 18% of the year. Different natural ventilation strategies were analysed: (a) three scenarios exploring different cross ventilation scenarios; (b) a scenario assuming that the church is closed all year round; and (c) a scenario estimating an increase in the number of visitors, giving an idea of the variations in human pollutants and possible consequences. Taking into account the air infiltration and the fact that masses, an occasional situation with a high number of visitors, are always held just before the church closes, it is guaranteed that carbon dioxide levels will never exceed the limit of 350 ppm above the outdoor values imposed by EN-13779, registering a maximum of 291 ppm.
Guilherme B. A. Coelho, Vasco Peixoto de Freitas, Fernando M. A. Henriques, and Hugo Entradas Silva
MDPI AG
Climate change will greatly influence the world at several levels and will have consequences on the interior climate of historic buildings and artifacts conservation. Buildings are responsible for a large slice of the overall emissions, which is due both to the greenhouse gases that are released during their construction as well as the activities that are performed therewithin. One way of counteracting this trend is to design more efficient retrofit buildings and predict their behavior using simulation software, which can thoroughly assess the performance of new buildings or the impact of each retrofit measure for existing buildings. In this study, a calibrated computational model of high thermal inertia building was used to assess the performance of passive retrofits in mitigating the effects of climate change concerning artifact decay mechanisms. In addition, a methodology that aims to reduce the amount of time spent to perform these studies is also presented, in which time savings reach up to 63%.
Hugo Entradas Silva and Fernando M.A. Henriques
Elsevier BV
Guilherme B.A. Coelho, Hugo Entradas Silva, and Fernando M.A. Henriques
Elsevier BV
Hugo Entradas Silva, Guilherme B.A. Coelho, and Fernando M.A. Henriques
Elsevier BV
Guilherme B.A. Coelho, Hugo Entradas Silva, and Fernando M.A. Henriques
Inderscience Publishers
Guilherme B.A. Coelho, Hugo Entradas Silva, and Fernando M.A. Henriques
Elsevier BV
Hugo Entradas Silva, Fernando M.A. Henriques, Telma A.S. Henriques, and Guilherme Coelho
Elsevier BV
Hugo Entradas Silva and Fernando M.A. Henriques
Emerald
Purpose – The purpose of this paper is to verify the applicability and efficiency of two statistical methods to obtain sustainable targets of temperature and relative humidity in historic buildings located in temperate climates. Design/methodology/approach – The data recorded along one year in a non-heated historic building in Lisbon (Portugal) was analysed with the two methodologies, EN 15757 and FCT-UNL. To evaluate their adequacy it was calculated the performance index for each target and it was verified the mechanical and biological degradation risks. Findings – While the use of the two approaches is suitable for temperate climates, there is a higher efficiency of the FCT-UNL methodology, allowing a better response for the three parameters in evaluation. Research limitations/implications – Despite the better results obtained, the FCT-UNL methodology was only tested for one city; therefore the application to other situations may be required to obtain more robust conclusions. Practical implications – The effectiveness of the FCT-UNL methodology to obtain sustainable climate targets can lead to important energy conservation in historic buildings and to contribute for the change of old approaches in the preventive conservation area. Originality/value – This paper provides a comparison between two recent methods. The results can lead to some advances in the science of preventive conservation, interesting to conservators and building physic scientists.
Hugo Entradas Silva and Fernando M.A. Henriques
Elsevier BV
Hugo Entradas Silva and Fernando M.A. Henriques
Elsevier BV