Maddalena Pennacchi
Verified @gmail.com
Scopus Publications
- Failure of Digital Device Performance in Monitoring Physical Exercise in a Pilot Study in Sedentary Persons with HIV
Matteo Bonato, Federica Marmondi, Filippo Turrini, Andrea Albergoni, Maddalena Pennacchi, Camilla Cerizza, Maria Francesca Piacentini, Antonella Castagna, Laura Galli, Francesco Sartor, Paola Cinque
Sensors, 2023
Digital devices have gained popularity in the last 10 years as a tool for exercise prescription, the monitoring of daily physical activity, and nutrition for the management of a health-related parameter. Therefore, the aim of this study was to assess the effectiveness of the use of digital devices to monitor exercise data in sedentary persons with HIV who exercise following an individualized activity pacing (AP) protocol on cardiorespiratory fitness body composition, blood lipid profile, and psychological parameters. Twenty-four PLWH were enrolled in an 18-week randomized, open-label, pilot AP exercise protocol. All participants were monitored by a Health Band connected to a mobile app that transmitted the data to a server. At week 3, they were randomized either in an experimental group (EG), in which an open device configuration enabled them to receive training data feedback (n = 12), or continued with no data feedback (control group, n = 12). The primary endpoint was improvement from the baseline of 15% of steady-state oxygen consumption (V˙O2) during a 6-min walking test. Technical issues occurred when pairing the health band with the app, which prevented EG participants from regularly receiving data feedback, and with data transmission to the server, which enabled only 40% monitoring of the total training days. Consequently, the study outcomes could not be compared between the two groups, and participants also lost confidence in the study. However, 19 out of 24 participants completed the AP program. Overall, only 6 (32%) improved steady-state V˙O2, with no significant changes at W18 from the baseline. Significant reductions were observed of BMI (p = 0.040), hip circumference (p = 0.027), and total-(p = 0.049) and HDL-cholesterol (p = 0.045). The failure of digital device performance substantially affected study procedures, monitoring, and participants’ engagement, and likely limited the potential benefits of the AP exercise program. - Monitoring rating of perceived exertion time in zone: A novel method to quantify training load in elite open-water swimmers?
Cristian Ieno, Roberto Baldassarre, Maddalena Pennacchi, Antonio La Torre, Marco Bonifazi, Maria Francesca Piacentini
International Journal of Sports Physiology and Performance, 2021
Purpose: To analyze training-intensity distribution (TID) using different independent monitoring systems for internal training load in a group of elite open-water swimmers. Methods: One hundred sixty training sessions were monitored in 4 elite open-water swimmers (2 females and 2 males: 23.75 [4.86] y, 62.25 [6.18] kg, 167 [6.68] cm) during 5 weeks of regular training. Heart-rate-based methods, such as time in zone (TIZ), session goal (SG), and hybrid (SG/TIZ), were used to analyze TID. Similarly to SG/TIZ, a new hybrid approach, the rating of perceived exertion (RPE)/TIZ for a more accurate analysis of TID was used. Moreover, based on the 3-zone model, the session ratings of perceived exertion of the swimmers and the coach were compared. Results: Heart-rate- and RPE-based TID methods were significantly different in quantifying Z1 (P = .012; effect size [ES] = 0.490) and Z2 (P = .006; ES = 0.778), while no difference was observed in the quantification of Z3 (P = .428; ES = 0.223). The heart-rate-based data for Z1, Z2, and Z3 were 83.2%, 7.4%, and 8.1% for TIZ; 80.8%, 8.3%, and 10.8% for SG/TIZ; and 55%, 15.6%, and 29.4% for SG. The RPE-based data were 70.9%, 19.9%, and 9.2% for RPE/TIZ% and 41.2%, 48.9%, and 9.7% for the session rating of perceived exertion. No differences were observed between the coach’s and the swimmers’ session ratings of perceived exertion in the 3 zones (Z1: P = .663, ES = −0.187; Z2: P = .110, ES = 0.578; Z3: P = .149, ES = 0.420). Conclusion: Using RPE-based TID methods, Z2 was significantly larger compared with Z1. These results show that RPE-based TID methods in elite open-water swimmers are affected by both intensity and volume. - Do the fastest open-water swimmers have a higher speed in middle- and long-distance pool swimming events?
Roberto Baldassarre, Maddalena Pennacchi, Antonio La Torre, Marco Bonifazi, Maria Piacentini
Journal of Functional Morphology and Kinesiology, 2019
Background: It has been shown that the fastest open-water swimmers (OW-swimmers) increase significantly the speed in the last split of the open-water events. The aim of the present work was to determine if the fastest OW-swimmers have a higher speed in the middle- and long-distance pool swimming events, and to develop a multivariate model that can predict the medalist group in the 10-km competition. Methods: A total of 484 athletes (252-males and 232-females) were included in the analysis. Swimmers were divided into four groups based on their finishing position in the competition. For each swimmer, the absolute best performance (PB) of 200, 400, 800 and 1500-meter in long course, the seasonal best performance (SPB) obtained before the open-water events and critical velocity (CV) were analyzed. Multivariate analysis of variance (MANOVA) was used to detect significant differences between groups and discriminant analysis was used to predict a grouping variable. Results: All the variables analyzed were significantly different between groups (p < 0.001). The first discriminant function correctly classified 50% of the overall female and male swimmers. Conclusion: Fastest OW-swimmers have a higher speed in middle- and long-distance pool swimming events. Further studies should include different anthropometric and physiological variables to increase the accuracy of classification.