Dr. ASWATHA

@bit-bangalore.edu.in

Professor
BANGALORE INSTITUTE OF TECHNOLOGY

Aswatha obtained his bachelor’s degree in
Mechanical Engineering from Bangalore
University, Bangalore in 1997. His
Masters and Ph.D. were obtained from
Visvevaraya Technological University,
Belgaum. He is presently working as
Professor in the Department of
Mechanical Engineering at Bangalore Institute of
Technology, Bangalore. His areas of interest are fluid flow,
natural convection heat and mass transfer in enclosures,
thermal management in data centers and electronic systems,
and computational fluid dynamics. He has about 30 international
journal publications.
I have 25 years of teaching experience. Guided 10 PhD Students.
LIC Member - VTU 2022 - 2023
Member Board of Examination (BOE) BU 2021 - 22 (ODD & EVEN)
GT&TC R&D Advisory Board Member Since 2020
Achievement: Top Downloaded Article Wiley 1 Jan 2021 - 31 Dec 2021

EDUCATION

BE, M Tech, PhD.

RESEARCH, TEACHING, or OTHER INTERESTS

Engineering, Mechanical Engineering, Computational Mechanics, Mechanics of Materials
18

Scopus Publications

123

Scholar Citations

7

Scholar h-index

6

Scholar i10-index

Scopus Publications

  • Power law coefficient effects on buoyant heat transfer in porous trapezoidal enclosures
    V. M. Vijaya Kumara, Aswatha, R. Vasanth Kumar, C. B. Hemanth Kumar, G. Mohan Kumar, R. Thejaraju, C. Manjunatha
    Interactions, 2026
  • Wear Behavior of AA2219-B4C Composite Fabricated via Stir Casting Followed by Age Hardening
    B. Supriya, Aswatha, Manjunath Bangalore Thimmaiah, S. ShivaPrakash, Avinash Lakshmikanthan, T. Jagadeesha
    Journal of the Institution of Engineers India Series D, 2025
  • Studies on the Buoyancy Effect in Right-Angled Trapezoidal Cavities
    V. M. Vijaya Kumara, Aswatha, Shekhar Tejas
    Lecture Notes in Mechanical Engineering, 2024
  • Effect of aspect ratio on the onset of natural convection in porous trapezoidal enclosures
    V.M. Vijaya Kumara, Aswatha, K.S. Pavan, A.S. Sagar Reddy, R.V. Sai charan, B.S. Sharath
    Materials Today Proceedings, 2023
  • Enhanced effectiveness with positive Joule–Thomson pressure drop effects on a cryogenic heat exchanger with three fluid-two communications
    Vishnudas Alias Vipul Luvu Chodankar, Aswatha Aswatha, K.N. Seetharamu
    International Journal of Numerical Methods for Heat and Fluid Flow, 2022
    Purpose The purpose of this paper is to attain higher effectiveness with an introduction of Joule–Thomson effect on a three-fluid heat exchanger with two communications. It also gives a range of parameter values that have to be maintained for achieving effectiveness above 0.85. Attaining effectiveness above 0.85 is very important for the heat exchanger to perform the liquefaction of hot fluid. Design/methodology/approach The analysis is conducted using Galerkin’s method, a finite element approach. Findings This investigation determines crucial values for the cryogenic heat exchanger to achieve effectiveness above 0.85. The important findings are as follows: effectiveness above 0.85 is attained if the heat exchanger size is within the range of 8–10; ratio of heat flow resistance between intermediate and hot stream to heat flow resistance between cold and hot stream should be maintained between 1 and 10; the intermediate fluid temperature should be maintained between 0 and 0.2; the ratio of thermal capacity of the hot fluid relative to a cold fluid should be maintained between 1.25 and 1.42; and the ratio of thermal capacity of the hot fluid relative to an intermediate fluid should be maintained between 2 and 2.5. Research limitations/implications The investigation has presented a finding for improving the effectiveness of the cryogenic heat exchanger. Higher the Joule–Thomson pressure drop effect, more is the drop in temperature of the fluid resulting in additional cooling or lowering of the fluid temperature. The practical implementation is also explained, i.e. to achieve practically the Joule–Thomson pressure drop in a cryogenic heat exchanger. Originality/value To the best of the authors’ knowledge, no investigations were carried out previously on Joule–Thomson investigation on a three-fluid heat exchanger with two communications, for different values of Joule–Thomson pressure drop.
  • Improved effectiveness of a cryogenic counter-current parallel flow - Three fluid heat exchanger with three thermal communication due to Joule Thomson pressure drop
    Vishnudas Alias Vipul L. Chodankar, Aswatha, K.N. Seetharamu
    International Journal of Thermal Sciences, 2022
  • Finite element analysis for free convection with in porous trapezoidal cavity
    V.M. Vijaya Kumara, Aswatha, K.N. Seetaramu
    Materials Today Proceedings, 2022
  • Joule–Thomson effect investigations on a cryogenic three-fluid–three thermal communication heat exchanger
    Vishnudas Alias Vipul L. Chodankar, Aswatha, V. Krishna, K. N. Seetharamu
    Heat Transfer, 2022
    The present study investigates the Joule–Thomson (JT) effect due to pressure drop on three‐fluid heat exchangers (HXs) with three thermal communications. The increased miniaturization of cryogenic HXs has led to the introduction of the JT effect. The present study investigates JT effects on a three‐fluid HX with three communications presenting different JT effects, which leads to a rise or drop in effectiveness values. The study is carried out using finite element analysis and MATLAB, considering seven nondimensional parameters of which one is JT pressure drop. The highest effectiveness is achieved for the positive JT effect at the hot stream. This improved effectiveness at hot fluid is achieved by maintaining the size (number of transfer units) of the HX more than 3.1, along with the ratio of the cold fluid heat capacity to the hot fluid heat capacity above 0.8 and the intermediate fluid temperature above 0.7.
  • Buoyant heat and flow circulation in a triangular porous cavity with radiation effect
    V M Vijaya Kumara, Aswatha, Sohan D'souza, Suvidh Subodh Hegde, Tejas N Kadlaskar, R. Yashwanth
    Materials Today Proceedings, 2022
  • The role of a partition on free convection in a trapezoidal shaped building
    R. Nagaraja, Aswatha, K. N. Seetharamu
    Heat Transfer, 2020
    Heat transfer and fluid flow in a partitioned trapezoidal‐shaped building are carried out. The finite‐volume computational procedure is adopted for numerical simulations. The inclined wall of the building is uniformly heated; the vertical wall is the cold wall, whereas the top and bottom walls are adiabatic. The ranges of parameters studied are the Rayleigh number, Ra (103 ≤ Ra ≤ 106), the location of the partition, d (0.3L ≤ d ≤ 0.9L), and the partition height, h (0.3H ≤ h ≤ 0.9H). The results are presented for different locations and height of the partition in an enclosure in terms of temperature patterns, streamline curves, and the local and overall Nusselt numbers. It is noticed that when the height of the partition increases beyond 0.3H irrespective of the position of the partition, the heat transfer decreases drastically for all Rayleigh numbers. The comfort zones are located in the cavity for different partition heights. Correlations are developed for Nusselt numbers in terms of the Rayleigh number and height of the partition.
  • Numerical Studies on Natural Convection in a Trapezoidal Enclosure With Discrete Heating
    Krishne Gowda B. Mote Gowda, Madurai S. Rajagopal, Aswatha, Kankanhalli N. Seethramu
    Heat Transfer Engineering, 2020
  • Effect of Joule-Thomson pressure drop on a cryogenic three fluid heat exchanger with two communications
    Vishnudas A.V.L. Chodankar, Aswatha, V. Krishna, K.N. Seetharamu
    Cryogenics, 2020
  • Heat transfer in a side heated trapezoidal cavity with openings
    B.M. Krishne Gowda, M.S. Rajagopal, Aswatha, K.N. Seetharamu
    Engineering Science and Technology an International Journal, 2019
  • Numerical investigations of conjugate natural convection in a square cavity filled with nanofluid with temperature variations onhorizontal walls
    International Conference on Computational Methods for Thermal Problems, 2018
  • Effect of joule-thomson pressure drop on the thermal performance of a three fluid heat exchanger with three communications, for cryogenic applications using finite element method
    International Conference on Computational Methods for Thermal Problems, 2018
  • Effect of convective boundary conditions at bottom wall on natural convections in a square cavity
    Journal of Engineering Science and Technology, 2013
  • Buoyancy driven heat transfer in cavities subjected to thermal boundary conditions at bottom wall
    Aswatha, C. J. G. Gowda, S. Sridhara, K. N. Seetharamu
    Journal of Applied Fluid Mechanics, 2012
  • Effect of different thermal boundary conditions at bottom wall on natural convection in cavities
    Journal of Engineering Science and Technology, 2011

RECENT SCHOLAR PUBLICATIONS

  • Power law coefficient effects on buoyant heat transfer in porous trapezoidal enclosures
    VM Vijaya Kumara, Aswatha, R Vasanth Kumar, CB Hemanth Kumar, ...
    Interactions 247 (1), 4 , 2026
    2026
  • Energy absorption and damage prediction in natural fibre composites under low velocity impact using machine learning and FEA
    SKSIAFE N. Rekha, Aswatha Munipapanna, N. Santhosh, Channa Keshava Naik N ...
    Scientific reports, https://doi.org/10.1038/s41598-025-24403 , 2025
    2025
    Citations: 2
  • Wear Behavior of AA2219‑B4C Composite Fabricated via Stir Casting Followed by Age Hardening
    BSAMBTSSPALT Jagadeesha
    J. Inst. Eng. India Ser. D , 2024
    2024
    Citations: 6
  • Studies on the Buoyancy Effect in Right-Angled Trapezoidal Cavities
    VM Vijaya Kumara, Aswatha, S Tejas
    ISME International Conference on Advances in Mechanical Engineering, 135-141 , 2023
    2023
  • Effect of aspect ratio on the onset of natural convection in porous trapezoidal enclosures
    BSS V.M. Vijaya Kumara, Aswatha, K.S. Pavan, A.S. Sagar Reddy, R.V. Sai charan
    Materials today 92, 314-321 , 2023
    2023
  • Enhanced effectiveness with positive Joule–Thomson pressure drop effects on a cryogenic heat exchanger with three fluid-two communications
    VAVL Chodankar, KN Seetharamu
    International Journal of Numerical Methods for Heat & Fluid Flow 32 (5 … , 2022
    2022
    Citations: 1
  • Improved effectiveness of a cryogenic counter-current parallel flow-Three fluid heat exchanger with three thermal communication due to Joule Thomson pressure drop
    VAVL Chodankar, KN Seetharamu
    International Journal of Thermal Sciences 172, 107267 , 2022
    2022
    Citations: 7
  • Improved effectiveness of a cryogenic counter-current parallel flow - Three fluid heat exchanger with three thermal communication due to Joule Thomson pressure drop
    KNS Vishnudas Alias Vipul L. Chodankar , Aswatha
    International Journal of Thermal Sciences , 2022
    2022
  • Joule–Thomson effect investigations on a cryogenic three‐fluid–three thermal communication heat exchanger
    VAVL Chodankar, Aswatha, V Krishna, KN Seetharamu
    Heat Transfer 51 (1), 866-890 , 2022
    2022
    Citations: 1
  • Structural Analysis of Non-pneumatic Tires with Hexagonal Spokes
    AM Kiran M., R. S. Charan, B. M. Sakshi, Akul Nikhil, Babu Rao Ponangi
    SAE International Journal , 2021
    2021
  • Effect of heat treatment on fatigue characteristics of EN8 Steel
    M Ravindran, M Aswatha, N Santhosh, G Ravichandran, M Madhusudhan
    IOP Conference Series: Materials Science and Engineering 1013 (1), 012009 , 2021
    2021
    Citations: 15
  • The role of a partition on free convection in a trapezoidal shaped building
    R Nagaraja, Aswatha, KN Seetharamu
    Heat Transfer 49 (7), 4056-4072 , 2020
    2020
  • Buoyant Energy Transmission within a Porous Square and Non-Square Cavity
    VKV MANCHAIAH
    International Journal of Science, Technology, Engineering and Management-A … , 2020
    2020
  • Buoyant Heat Transfer in a Porous Cavity of Trapezoidal Shape
    VKV MANCHAIAH
    International Journal of Science, Technology, Engineering and Management-A … , 2020
    2020
  • Numerical studies on natural convection in a trapezoidal enclosure with discrete heating
    KGBM Gowda, MS Rajagopal, KN Seethramu
    Heat Transfer Engineering , 2020
    2020
    Citations: 19
  • Effect of Joule-Thomson pressure drop on a cryogenic three fluid heat exchanger with two communications
    VAVL Chodankar, V Krishna, KN Seetharamu
    Cryogenics 106, 103046 , 2020
    2020
    Citations: 5
  • Natural Convection in a Square Enclosure with Partitions
    KNS R. Nagaraja, Aswatha, Vijay Kumar V. M
    Studies in Indian Place Names (UGC Care Journals) 40 (71) , 2020
    2020
  • Heat transfer in a side heated trapezoidal cavity with openings
    BMK Gowda, MS Rajagopal, KN Seetharamu
    Engineering Science and Technology, an International Journal 22 (1), 153-167 , 2019
    2019
    Citations: 18
  • EFFECT OF CONJUGATE NATURAL CONVECTION FLOW IN A SQUARE ENCLOSURE WITH ALL SIDE WALL
    B Babali, KN Seetharamu
    Proceedings of the 24th National and 2nd International ISHMT-ASTFE Heat and … , 2017
    2017
  • Computational analysis and design for precision forging of aluminium AA 6061 connector
    N Santhosh, N Vinayaka, MU Aswatha, BA Praveena
    International Journal of Computational Engineering Research 3 (9), 1-8 , 2013
    2013
    Citations: 10

MOST CITED SCHOLAR PUBLICATIONS

  • Effect of different thermal boundary conditions at bottom wall on natural convection in cavities
    K Seetharamu
    Journal of Engineering Science and Technology 6 (1), 109-130 , 2011
    2011
    Citations: 22
  • Numerical studies on natural convection in a trapezoidal enclosure with discrete heating
    KGBM Gowda, MS Rajagopal, KN Seethramu
    Heat Transfer Engineering , 2020
    2020
    Citations: 19
  • Heat transfer in a side heated trapezoidal cavity with openings
    BMK Gowda, MS Rajagopal, KN Seetharamu
    Engineering Science and Technology, an International Journal 22 (1), 153-167 , 2019
    2019
    Citations: 18
  • Buoyancy driven heat transfer in cavities subjected to thermal boundary conditions at bottom wall
    CJ Gangadhara Gowda, SN Sridhara, KN Seetharamu
    Journal of Applied Fluid Mechanics 5 (2), 43-53 , 2012
    2012
    Citations: 17
  • Effect of heat treatment on fatigue characteristics of EN8 Steel
    M Ravindran, M Aswatha, N Santhosh, G Ravichandran, M Madhusudhan
    IOP Conference Series: Materials Science and Engineering 1013 (1), 012009 , 2021
    2021
    Citations: 15
  • Computational analysis and design for precision forging of aluminium AA 6061 connector
    N Santhosh, N Vinayaka, MU Aswatha, BA Praveena
    International Journal of Computational Engineering Research 3 (9), 1-8 , 2013
    2013
    Citations: 10
  • Improved effectiveness of a cryogenic counter-current parallel flow-Three fluid heat exchanger with three thermal communication due to Joule Thomson pressure drop
    VAVL Chodankar, KN Seetharamu
    International Journal of Thermal Sciences 172, 107267 , 2022
    2022
    Citations: 7
  • Wear Behavior of AA2219‑B4C Composite Fabricated via Stir Casting Followed by Age Hardening
    BSAMBTSSPALT Jagadeesha
    J. Inst. Eng. India Ser. D , 2024
    2024
    Citations: 6
  • Effect of Joule-Thomson pressure drop on a cryogenic three fluid heat exchanger with two communications
    VAVL Chodankar, V Krishna, KN Seetharamu
    Cryogenics 106, 103046 , 2020
    2020
    Citations: 5
  • Energy absorption and damage prediction in natural fibre composites under low velocity impact using machine learning and FEA
    SKSIAFE N. Rekha, Aswatha Munipapanna, N. Santhosh, Channa Keshava Naik N ...
    Scientific reports, https://doi.org/10.1038/s41598-025-24403 , 2025
    2025
    Citations: 2
  • Enhanced effectiveness with positive Joule–Thomson pressure drop effects on a cryogenic heat exchanger with three fluid-two communications
    VAVL Chodankar, KN Seetharamu
    International Journal of Numerical Methods for Heat & Fluid Flow 32 (5 … , 2022
    2022
    Citations: 1
  • Joule–Thomson effect investigations on a cryogenic three‐fluid–three thermal communication heat exchanger
    VAVL Chodankar, Aswatha, V Krishna, KN Seetharamu
    Heat Transfer 51 (1), 866-890 , 2022
    2022
    Citations: 1
  • Power law coefficient effects on buoyant heat transfer in porous trapezoidal enclosures
    VM Vijaya Kumara, Aswatha, R Vasanth Kumar, CB Hemanth Kumar, ...
    Interactions 247 (1), 4 , 2026
    2026
  • Studies on the Buoyancy Effect in Right-Angled Trapezoidal Cavities
    VM Vijaya Kumara, Aswatha, S Tejas
    ISME International Conference on Advances in Mechanical Engineering, 135-141 , 2023
    2023
  • Effect of aspect ratio on the onset of natural convection in porous trapezoidal enclosures
    BSS V.M. Vijaya Kumara, Aswatha, K.S. Pavan, A.S. Sagar Reddy, R.V. Sai charan
    Materials today 92, 314-321 , 2023
    2023
  • Improved effectiveness of a cryogenic counter-current parallel flow - Three fluid heat exchanger with three thermal communication due to Joule Thomson pressure drop
    KNS Vishnudas Alias Vipul L. Chodankar , Aswatha
    International Journal of Thermal Sciences , 2022
    2022
  • Structural Analysis of Non-pneumatic Tires with Hexagonal Spokes
    AM Kiran M., R. S. Charan, B. M. Sakshi, Akul Nikhil, Babu Rao Ponangi
    SAE International Journal , 2021
    2021
  • The role of a partition on free convection in a trapezoidal shaped building
    R Nagaraja, Aswatha, KN Seetharamu
    Heat Transfer 49 (7), 4056-4072 , 2020
    2020
  • Buoyant Energy Transmission within a Porous Square and Non-Square Cavity
    VKV MANCHAIAH
    International Journal of Science, Technology, Engineering and Management-A … , 2020
    2020
  • Buoyant Heat Transfer in a Porous Cavity of Trapezoidal Shape
    VKV MANCHAIAH
    International Journal of Science, Technology, Engineering and Management-A … , 2020
    2020